How to Solve DEUTZ EMR3 Engine 37 / 111 / CLSCDSysReacA Story by carHow to repair Deutz EMR3 engine controller fault 37 / 111 / CLSCDSysReacHow to repair Deutz EMR3 engine controller fault 37 / 111 / CLSCDSysReac Possible FMI: 1: data valid, but below normal working area 1: data valid, but below normal working area 12. Errormode not identifiable 12. Errormode not identifiable Errordetection Errorlamp shows permanent light oder blinking. Entry in errormemory. Possible reason for error Outside target range with system reaction, cooling system untight, sensor defective, onnection cable demaged Take actions for error repair Check coolant level, check cabling, inspect cooling system and if necessary repair it, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it Other error properties System reaction: Advice: CLSCD_stSysReacReq Behaviour error lamp: permanent light oder blinking Selfhealing: no Signal Priority: 3 Measurement @ errortime: actual value © 2025 car |
Stats
335 Views
Added on April 23, 2025 Last Updated on April 23, 2025 |


Flag Writing